INTRODUCTION This manual has been prepared primarily for the use of Designers/Installers of INERGEN (300 bar) Fire Fighting Equipment. Its purpose is to provide general information on Inergen and its use in Fire Fighting systems and to give more detailed information covering the design, installation, testing and servicing of these systems. Sep 02, 2020 Ansul Inergen Clean-Agent Fire Suppression Systems. You then have a choice of setting up your cylinders to open electrically, pneumatically or manually, depending on your need. Jnergen is listed and approved by governmental, nationally and internationally recognized testing laboratories. INERGEN agent is stored as a gaseous mixture in DOT-approved steel cylinders filled to nominal capacities of 200 to 435 cu. (5.7 to 12.3 cu. Available in four sizes, you can choose to install your cylinders either vertically or horizontally, allowing for a design that requires the fewest number of cylinders and the lowest cost.
For businesses located in Tennessee, Mississippi and Arkansas, State Systems Inc. offers installation, inspection, repair and maintenance services for:
- Ansul SAPPHIRE Novec 1230
- Ansul INERGEN
- Ansul R102 Restaurant Fire Suppression System
- Ansul PIRHANA Restaurant Fire Suppression System
- Ansul Carbon Dioxide Systems
- Ansul Vehicle Fire Suppression System
To learn more about each Ansul fire suppression system, keep reading—or call us today at 901-531-6550 to discuss which is best for your property and request an estimate.
A proud Ansul Double Diamond Alliance Partner, State Systems specializes in the installation of Ansul fire suppression systems that work as clean agent fire suppression mechanisms to protect your Mid-South property and all that is inside. The Diamond Alliance recognizes Ansul system distributors for outstanding performance in the sale of special-hazards fire protection equipment. Less than 20 percent of Ansul distributors have Diamond Alliance Partner distinction. Ansul itself is a premium brand of Tyco Fire Suppression & Building Products.
Ansul SAPPHIRE Novec 1230
The Ansul SAPPHIRE Novec 1230 is a highly effective system that serves as a powerful clean agent fire suppression method. Instead of using water to extinguish a fire, this clean agent system is custom-engineered to suppress fires safely, rapidly and efficiently while still protecting your expensive electronic equipment.
The heart of this Ansul system is the revolutionary 3M SAPPHIRE Novec 1230 fire protection fluid—a clear, colorless, and odorless clean agent. By instantly vaporizing upon discharge, the clean agent used can complete flood protected areas to suffocate the fire and absorb heat. This sophisticated Ansul system suppresses a fire before it can start by detecting it at invisible levels. It also quickly evaporates after the danger has passed, ensuring your valuable assets aren’t harmed.
This Ansul system is typically installed in facilities and area where:
![Brooks kubik chalk and sweat pdf printable Brooks kubik chalk and sweat pdf printable](http://superstrengthtraining.com/wp-content/uploads/2015/12/Kubik-5-2.jpg)
- An electronically non-conducive medium is required.
- Electronic systems cannot be shut down in the case of an emergency.
- Large groups of people gather, making it essential that a non-toxic agent is used.
In accordance with NFPA 2001, the SAPPHIRE Novec 1230 is safe for use in occupied spaces.
Additionally, with an ozone depletion potential (ODP) of zero and a global warming potential (GWP) of one, this Ansul system is among the most environmentally friendly clean agent fire suppression systems available on the market today.
Ansul INERGEN
The Ansul INERGEN is another very effective fire suppression system that protects enclosed areas where there is a high need for quickly reacting to and suppressing a fire. Fire protection technicians choose this system when there are typically large groups of people present in the area and traditional suppression agents are not safe for use.
Inergen Installation Manual Pdf
The Ansul INERGEN uses a clean agent composed of three naturally occurring gases found in the air we breathe:
- Nitrogen
- Argon
- Trace amounts of carbon dioxide
![Inergen Installation Manual Inergen Installation Manual](https://www.inertgasfiresystems.com/wp-content/uploads/2018/08/Inergen.jpg)
Leaving behind no residue and with an ODP and GWP of zero, the Ansul INERGEN is the most environmentally friendly fire suppression system on the market. Unlike halocarbon alternatives, which create dangerous levels of hydrogen fluoride in the presence of fires, this Ansul system is completely nontoxic. Additionally, it does not produce any fog when in operation, leaving escape routes visible. The advanced Ansul INERGEN can detect a fire even before it reaches the flame stage.
Ansul R102 Restaurant Fire Suppression System
The Ansul R-102 Liquid Agent System is the best protector and defender of today’s kitchen equipment and commercial restaurants, and you can choose from two design options.
The first is the appliance-specific design. With the appliance-specific design, the most efficient fire protection is accomplished when nozzles are selected and aimed at specific hazard areas on each appliance—especially where grease and flames might meet. This method usually offers the most economical use of liquid agent, reducing the size or quantity of storage tanks and associated hardware.
The second design option is the overlapping appliance protection. When flexibility and simplicity are the main priorities for restaurant managers, nozzles are placed in a straight-line arrangement, providing overlapping agent discharge patterns. This forms a virtual fire-free zone where appliances of various types and sizes are protected, even if they are replaced or rearranged under the hood.
Call us at 901-531-6550 to learn more about Ansul R102 Restaurant fire suppression systems.
Ansul PIRANHA Restaurant Fire Suppression System
The Ansul PIRANHA Restaurant fire suppression system is a dual agent, pre-engineered, fixed, system specially designed to protect the following areas associated with cooking equipment:
- Hoods
- Ducts
- Plenums
- Filters
- Fryers
- Griddles and range tops
- Upright, natural charcoal, and chain-type broilers
- Electric, lava rock, mesquite, and gas-radiant bar-broilers
- Woks
- And more
This system is suitable for use in restaurants, hospitals, nursing homes, hotels, schools, airports, and other similar facilities. When actuated, the system discharges a fixed amount of proprietary wet chemical agent followed by water through the same nozzles (provided by a connection to the portable water supply). Contact State Systems to learn more about the Ansul PIRANHA restaurant fire suppression system.
Ansul Carbon Dioxide Systems
Carbon dioxide is the original “clean” agent—it suppresses fire without leaving behind an agent to damage sensitive (and expensive) equipment. Best of all, there’s no residue to clean up, ensuring that you’re back in business faster. Ansul High Pressure Carbon Dioxide Systems are highly effective for non-occupied hazards such as:
![Inergen installation manual pdf Inergen installation manual pdf](https://image.slidesharecdn.com/inergenppt070820121-120807120555-phpapp02/95/inergen-77-728.jpg?cb=1344353680)
- Semiconductor wet benches
- Control rooms
- Paint lines
- Vaults
- Flammable gas or liquid storage areas
- Printing presses
- And more
Whatever the application, from cylinder to nozzle, each system is custom-designed for the specific fire hazards in your Mid-South building or facility.
Ansul Vehicle Fire Suppression System
State Systems is also proud to carry Ansul Vehicle Fire Suppression Systems. These systems were invented and introduced in the 1960s in order to protect commercial vehicles and moving equipment. As mobile equipment has grown in size and complexity since then, so have these vehicle fire suppression systems.
Since statistics have shown that on-road vehicles burn with alarming frequency, commercial vehicles are vulnerable to fire for a variety of reasons:
- They often operate steady for several hours at a time
- They use flammable liquids, including oil, gasoline, diesel oil, greases, and hydraulic fluids
- They generate heat from engine blocks, manifolds, turbocharges, and brake charges
When put together, all of these components can ignite the flammable liquids and debris.
Owners of vehicles equipped with an Ansul Fire Suppression System have taken an important step in facing the fire problem. Call us or contact us online to learn more or request an estimate for your commercial fleet.
Ansul Fire Suppression Installation & Inspection in TN, MS & AR
We offer Ansul system installation, inspection, and maintenance services in these cities and their surrounding areas:
- Arkansas (AR): Blytheville, Forrest City, Helena-West Helena, Jonesboro, Marion, Paragould, and Wynne
- Mississippi (MS): Batesville, Clarksdale, Cleveland, DeSoto County, Greenville, Greenwood, Grenada, Hernando, Horn Lake, Olive Branch, Oxford, Senatobia, Southaven, Tunica, and Tupelo
- Tennessee (TN): Arlington, Bartlett, Collierville, Dyersburg, Fayette County, Germantown, Jackson, Lakeland, Martin, Memphis, Millington, Tipton County, and Union City
To learn more about the Ansul systems we can install for your Mid-South business, or for an estimate, contact us online or call 901-531-6550. Latest scrivener 2.5 crack mac full version 2016 download. We will help determine which Ansul system is most appropriate for your business and your needs in order to best protect your property, life, and assets.
Ansul Inergen Installation Manual
“State Systems is one of the top names in this line of business. You are dealing with a reputable company that knows how to take care of its customers. I couldn’t do what I do without the support of the State Systems team. They have made my job that much easier.” – Gene Brinkley, Facility Manager for Woodland Presbyterian Church and School
INERGEN® is a mixture of 52% Nitrogen, 40% Argon and 8% CO2. However, in the event of a fire, when INERGEN® is discharged, it mixes with the air present in the room to create a mixture that comprises of 67.3% Nitrogen, 12.5% Oxygen, 17% Argon and 3.2% Carbon Dioxide.
This discharge mixture makes INERGEN® singularly unique. No other inert gas has the unique ability to rapidly extinguish a fire yet at the same time provide a safe environment for any person within the occupied area by actually decreasing cardiac distress and maintaining arterial blood oxygenation and mental performance in low oxygen levels.
Equally important, unlike some chemical gaseous fire suppression agents, INERGEN® does not, and could never create a reaction with a fire to create extremely harmful toxic or corrosive by-products.
INERGEN has been extensively used throughout the world as a preferred gaseous fire suppression agent for over 16 years and remains the longest surviving Halon replacement on the market to date.
Cost studies have shown that INERGEN is cost competitive when compared with the most popular chemical agents on typical systems. INERGEN does not take up premium floor space as the cylinders can be placed remotely from the protected risk.
What types of INERGEN® system are available?
There are three types of INERGEN® system available, subject to the type of fire risk involved.
INERGEN® Premier Gaseous Fire Suppression Systems
INERGEN® Premier is a 300 bar inert gaseous fire suppression system ideally suited for large “Multiple Area Protection.” It is controlled by a BS 7273 analogue/addressable fire detection and alarm system specifically designed and dedicated for gas release. more
INERGEN® Conventional Gaseous Fire Suppression Systems
INERGEN® Conventional 300 bar inert gaseous fire suppression systems are ideally suited for medium sized “Business Critical Areas” of protection.” It is controlled by a Conventional fire detection and alarm system specifically designed and dedicated for gas release. more
Software Installation Manual
INERGEN® Direct Orifice System Gaseous Fire Suppression
Inergen Installation Manual Download
This type of system has been specifically designed for very small “Business Critical Areas” of protection.” Mechanical design modifications to the manifold distribution system make it an extremely cost effective method of protecting valuable sensitive electrical equipment. more